Get In Touch
Get In Touch +1 (888) 575-2099
Dial +1 (888) 575-2099
grab it before it's gone.
As low as possible.
Never used.
$200.00
$70.00
$100.00
$30.00
$300.00
$100.00
Products added to cart!
The PCE PCO 2 Particle Counter Air Sampler is designed to monitor particulate matter (PM) concentrations in the air. It supports indoor air quality (IAQ) assessments and can also measure air temperature, dew point, and relative humidity.
This particle counter is ideal for monitoring clean rooms, exposure to exhaust, smoke and other harmful air pollutants, and levels of airborne combustible dust such as agricultural dust, carbonaceous dust, chemical dust, metal dust, plastic dust and wood dust.
A variety of materials are explosive / flammable in dust form. Some examples include: food (e.g., candy, sugar, spice, starch, flour and feed), grain, tobacco, plastics, wood, paper, pulp, rubber, pesticides, pharmaceuticals, dyes, coal and metals (e.g., aluminum, chromium, iron, magnesium and zinc). These materials are used in agriculture, chemical manufacturing, pharmaceutical production, furniture, textiles, fossil fuel power generation, recycling operations, metal working and processing (including additive manufacturing and 3D printing) and many other industries and processes.
In addition to being a combustion hazard, certain kinds of dust can be a health hazard. Exposure (such as skin contact, eye contact and inhalation) can be linked to sneezing, a stuffy or runny nose, itchy or red eyes, headaches, fatigue, fever, cough, shortness of breath, dermatitis, asthma, bronchitis, pneumonia (e.g., Legionnaires’ disease and hypersensitivity pneumonitis) and cancer.
When inhaled, PM 2.5 and PM 10 particles can settle deep into the lungs and result in damaging health effects. Since the PCE-PCO 2 particle counter monitors PM 2.5 and PM 10 particles, the device has many practical health and safety applications. Heating, ventilation and air conditioning (HVAC) technicians use PM 2.5 and PM 10 particle counters for HVAC system performance and filtration audits. In addition, industrial hygienists and workplace safety professionals rely on PM 2.5 and PM 10 particle counters when evaluating occupational health and safety risks related to hazardous and combustible dust.
Particulate Matter Channels | PM 2.5 / PM 10 |
---|---|
Particle Concentration Range | 0 – 2000 µg / m³ |
Resolution | 1 µg / m³ |
Particle Sizes | 0.3 / 0.5 / 1.0 / 2.5 / 5.0 / 10 µm |
Flow Rate | 2.83 l / min |
Coincidence Error | < 5 % at 2,000,000 particles/ft³ |
Counting Efficiency | 50 % at 0.3 µm |
100 % for particle size > 0.45 µm | |
Memory Capacity | Stores up to 5,000 data sets |
Counting Modes | Cumulative, differential, concentration |
Air Temp. Measuring Range | 0 – +50 °C / +32 – +122 °F |
Dew Point Temp. Range | 0 – +50 °C / +32 – +122 °F |
Humidity Measuring Range | 0 – 100 % RH |
Air Temp. Accuracy | +10 – +40 °C: ± 0.5 °C |
Others: ± 1 °C | |
Dew Point Accuracy | 0 – +10 °C: ± 1 °C |
+10 – +40 °C: ± 0.5 °C | |
Humidity Accuracy | 0 – 20 % RH: ± 5 % |
Operating Conditions | 0 – +50 °C / +32 – +122 °F |
10 – 90 % RH, non-condensing | |
Storage Conditions | -10 – +60 °C / +14 – +140 °F |
10 – 90 % RH, non-condensing | |
Display | 2.8", 320 × 240 pixel, backlit TFT color LCD |
Power Supply | 1 × rechargeable battery |
Battery Life | Approx. 4 hours continuous use |
Battery Recharge Time | Approx. 2 hours with AC charger |
Indoor Air Quality Monitoring: Specifically designed to assess particulate matter (PM) concentrations, ensuring optimal air quality in indoor environments.
Multi-Parameter Measurement: In addition to particles, it tracks air temperature, dew point, and relative humidity, offering a comprehensive view of environmental conditions.
Accurate and Reliable: Provides precise air quality measurements, making it essential for cleanrooms, offices, laboratories, and other sensitive environments.
User-Friendly: Easy to operate, compact, and portable, making it convenient for both on-site and routine monitoring tasks.
Versatile Applications: Ideal for use in industries that require strict environmental control, such as healthcare, pharmaceuticals, and HVAC systems.
Q: What does the PCE PCO 2 measure?
A: It monitors particulate matter (PM) concentrations in the air, helping to assess indoor air quality (IAQ).
Q: What additional environmental factors can the PCE PCO 2 measure?
A: It also measures air temperature, dew point, and relative humidity.
Q: Why is the PCE PCO 2 important for air quality monitoring?
A: It provides comprehensive data on particulate matter and environmental conditions, ensuring safe and compliant air quality.
Q: Where can the PCE PCO 2 be used?
A: Ideal for use in offices, clean rooms, factories, and other indoor environments where air quality is a concern.
Clean the air intake regularly using compressed air or a soft brush to prevent buildup.
Calibrate periodically to ensure accurate particulate matter measurements.
Check the sensor for obstructions or dust accumulation, which can affect readings.
Inspect and replace filters as needed to maintain optimal airflow and accuracy.
Store the device in a dry, dust-free location when not in use to protect sensitive components.
Monitor battery levels and recharge or replace as needed for continuous operation.
Thanks for subscribing!