PCE PCO 2 Partical Counter Air Sampler -PCE-PCO 2

FREE SHIPPING
CLEARANCE SALE
80 Peoples are also watching.
Brand: PCE
SKU: PCE-PCO 2
$1,280.60
$1,534.00
$1,280.60
Subtotal: $1,280.60
clearance sale ends in
00 Hours
00 Minutes
00 Seconds
authorized dealer, shop your favorite brand.
Expert Support,

Dial +1 (888) 575-2099

Limited Supply,

grab it before it's gone.

Lowest prices,

As low as possible.

All Items are brand New,

Never used.

Popular Add-Ons

$200.00

$70.00

$100.00

$30.00

Add-Ons Bundle

$200.00

$70.00

$100.00

$30.00

Bundle Offer

$300.00

$100.00

Recently Viewed Products

PCE PCO 2 Partical Counter Air Sampler -PCE-PCO 2

        The PCE PCO 2 Particle Counter Air Sampler is designed to monitor particulate matter (PM) concentrations in the air. It supports indoor air quality (IAQ) assessments and can also measure air temperature, dew point, and relative humidity.

        This particle counter is ideal for monitoring clean rooms, exposure to exhaust, smoke and other harmful air pollutants, and levels of airborne combustible dust such as agricultural dust, carbonaceous dust, chemical dust, metal dust, plastic dust and wood dust.

        A variety of materials are explosive / flammable in dust form. Some examples include: food (e.g., candy, sugar, spice, starch, flour and feed), grain, tobacco, plastics, wood, paper, pulp, rubber, pesticides, pharmaceuticals, dyes, coal and metals (e.g., aluminum, chromium, iron, magnesium and zinc). These materials are used in agriculture, chemical manufacturing, pharmaceutical production, furniture, textiles, fossil fuel power generation, recycling operations, metal working and processing (including additive manufacturing and 3D printing) and many other industries and processes.

        In addition to being a combustion hazard, certain kinds of dust can be a health hazard. Exposure (such as skin contact, eye contact and inhalation) can be linked to sneezing, a stuffy or runny nose, itchy or red eyes, headaches, fatigue, fever, cough, shortness of breath, dermatitis, asthma, bronchitis, pneumonia (e.g., Legionnaires’ disease and hypersensitivity pneumonitis) and cancer.

        When inhaled, PM 2.5 and PM 10 particles can settle deep into the lungs and result in damaging health effects. Since the PCE-PCO 2 particle counter monitors PM 2.5 and PM 10 particles, the device has many practical health and safety applications. Heating, ventilation and air conditioning (HVAC) technicians use PM 2.5 and PM 10 particle counters for HVAC system performance and filtration audits. In addition, industrial hygienists and workplace safety professionals rely on PM 2.5 and PM 10 particle counters when evaluating occupational health and safety risks related to hazardous and combustible dust.

        Highlights
        • Portable
        • Handheld
        • Great for monitoring particulate matter (PM) concentrations in the air
        • 0.3 µm, 0.5 µm, 1.0 µm, 2.5 µm, 5.0 µm and 10 µm particle sizes 
        • Measures air temperature, dew point and relative humidity
        Features
        • Captures 6 particle sizes
        • Measures air temperature, dew point and relative humidity
        • 2.8" TFT full-color LCD screen
        • Built-in camera for image and video recording
        • Cumulative, differential and concentration particle counting modes
        • Stores up to 5,000 data sets to memory
        • Power-saving automatic shutdown feature
        • PM channels: PM 2.5, PM 10, including mass concentration mode (µg/m³)
        • Free software download on PCE Software web page
          Specifications
          Particulate Matter Channels PM 2.5 / PM 10
          Particle Concentration Range 0 – 2000 µg / m³
          Resolution 1 µg / m³
          Particle Sizes 0.3 / 0.5 / 1.0 / 2.5 / 5.0 / 10 µm
          Flow Rate 2.83 l / min
          Coincidence Error < 5 % at 2,000,000 particles/ft³
          Counting Efficiency 50 % at 0.3 µm
          100 % for particle size > 0.45 µm
          Memory Capacity Stores up to 5,000 data sets
          Counting Modes Cumulative, differential, concentration
          Air Temp. Measuring Range 0 – +50 °C / +32 – +122 °F
          Dew Point Temp. Range 0 – +50 °C / +32 – +122 °F
          Humidity Measuring Range 0 – 100 % RH
          Air Temp. Accuracy +10 – +40 °C: ± 0.5 °C
          Others: ± 1 °C
          Dew Point Accuracy 0 – +10 °C: ± 1 °C
          +10 – +40 °C: ± 0.5 °C
          Humidity Accuracy 0 – 20 % RH: ± 5 %
          Operating Conditions 0 – +50 °C / +32 – +122 °F
          10 – 90 % RH, non-condensing
          Storage Conditions -10 – +60 °C / +14 – +140 °F
          10 – 90 % RH, non-condensing
          Display 2.8", 320 × 240 pixel, backlit TFT color LCD
          Power Supply 1 × rechargeable battery
          Battery Life Approx. 4 hours continuous use
          Battery Recharge Time Approx. 2 hours with AC charger
          What's included
          • 1 x PCE-PCO 2 air sampler
          • 1 x zero filter
          • 1 x rechargeable battery
          • 1 x AC charger
          • 1 x USB cable
          • 1 x user manual
          • 1 x CD-ROM (software)
          • 1 x mini tripod
          • 1 x hard case
          Manual

          PCE-PCO 2 User Manual

          PCE-PCO 2 Data Sheet

          What Our Experts Think
          • Indoor Air Quality Monitoring: Specifically designed to assess particulate matter (PM) concentrations, ensuring optimal air quality in indoor environments.

          • Multi-Parameter Measurement: In addition to particles, it tracks air temperature, dew point, and relative humidity, offering a comprehensive view of environmental conditions.

          • Accurate and Reliable: Provides precise air quality measurements, making it essential for cleanrooms, offices, laboratories, and other sensitive environments.

          • User-Friendly: Easy to operate, compact, and portable, making it convenient for both on-site and routine monitoring tasks.

          • Versatile Applications: Ideal for use in industries that require strict environmental control, such as healthcare, pharmaceuticals, and HVAC systems.

          Q&A

          Q: What does the PCE PCO 2 measure?
          A: It monitors particulate matter (PM) concentrations in the air, helping to assess indoor air quality (IAQ).

          Q: What additional environmental factors can the PCE PCO 2 measure?
          A: It also measures air temperature, dew point, and relative humidity.

          Q: Why is the PCE PCO 2 important for air quality monitoring?
          A: It provides comprehensive data on particulate matter and environmental conditions, ensuring safe and compliant air quality.

          Q: Where can the PCE PCO 2 be used?
          A: Ideal for use in offices, clean rooms, factories, and other indoor environments where air quality is a concern.

          Maintenance Tips
          • Clean the air intake regularly using compressed air or a soft brush to prevent buildup.

          • Calibrate periodically to ensure accurate particulate matter measurements.

          • Check the sensor for obstructions or dust accumulation, which can affect readings.

          • Inspect and replace filters as needed to maintain optimal airflow and accuracy.

          • Store the device in a dry, dust-free location when not in use to protect sensitive components.

          • Monitor battery levels and recharge or replace as needed for continuous operation.

                    Related Products

                    Brand: Brand
                    Example product title
                    $1,280.60
                    $1,534.00
                    $1,280.60
                    Brand: Brand
                    Example product title
                    $1,280.60
                    $1,534.00
                    $1,280.60
                    Brand: Brand
                    Example product title
                    $1,280.60
                    $1,534.00
                    $1,280.60
                    Brand: Brand
                    Example product title
                    $1,280.60
                    $1,534.00
                    $1,280.60