Taco Hot Water Circulator Pump 1/25 HP - 007-SF5-IFC

FREE SHIPPING
CLEARANCE SALE
80 Peoples are also watching.
Brand: Taco
SKU: 007-SF5-IFC
$577.29
$0.00
$577.29
Subtotal: $577.29
clearance sale ends in
00 Hours
00 Minutes
00 Seconds
authorized dealer, shop your favorite brand.
Expert Support,

Dial +1 (888) 575-2099

Limited Supply,

grab it before it's gone.

Lowest prices,

As low as possible.

All Items are brand New,

Never used.

Popular Add-Ons

$200.00

$70.00

$100.00

$30.00

Add-Ons Bundle

$200.00

$70.00

$100.00

$30.00

Bundle Offer

$300.00

$100.00

Recently Viewed Products

Taco Hot Water Circulator Pump 1/25 HP - 007-SF5-IFC

The Taco 007-SF5-IFC is a stainless steel circulator pump designed for efficient hot water circulation. With a horsepower of 1/25, this pump operates on a voltage of one hundred fifteen volts. The integral flow check helps streamline installation and improve the overall performance of HVAC systems.

This circulator pump is ideal for hydronic heating systems, hydro-air fan coils, radiant heating, and domestic water recirculation.

Features
  • Removable Integral Flow Check enhances pump operation
  • Designed to prevent reverse flow and reduce installation costs
  • Durable stainless steel construction offers reliability
Specifications
Brand Taco
Model Number 007-SF5-IFC
Horsepower 1/25 hp
Voltage 115V
Flow Rate 17 GPM
Maximum RPM 3250
Material Stainless Steel
Maximum Pressure 125 PSI
Temperature Range 40°F to 230°F
Connection Type Flanged x Flanged
Connection Sizes 3/4", 1", 1-1/4", 1-1/2"

What Our Experts Think
  • Energy-Efficient Performance: This compact pump delivers excellent performance for hydronic systems, providing up to 23 GPM flow rate with a 10-foot head, making it perfect for residential and light commercial use.

  • Built-In Flow Check (IFC®): The integrated flow check valve prevents gravity flow, simplifying system design by eliminating the need for an additional in-line check valve.

  • Quiet & Reliable: Designed for quiet operation, it's ideal for areas where noise is a concern, like homes or offices.

  • Stainless Steel Durability: The stainless steel construction ensures longevity and resistance to corrosion, making it perfect for long-term use in hydronic and radiant heating systems.

  • Maintenance-Free Design: With its self-lubricating, wet rotor design, this circulator requires minimal upkeep, lowering maintenance costs over time.

Q&A

Q: What is the Taco 007-SF5-IFC?
A: The Taco 007-SF5-IFC is a stainless steel, wet-rotor, in-line circulator pump designed for hydronic heating, radiant heating, and domestic water recirculation systems.

Q: What is the Integral Flow Check (IFC)?
A: The IFC is a built-in feature that prevents gravity and reverse flow, eliminating the need for a separate in-line check valve, simplifying installation, and improving system performance.

Q: Is the pump easy to maintain?
A: Yes, it has a field-serviceable cartridge design, making it easy to maintain and replace without removing the entire unit.

Q: What are the typical applications of this pump?
A: It's ideal for hydronic heating systems, radiant floor heating, indirect water heaters, chilled water systems, and domestic hot water recirculation

Maintenance Tips
  • Self-Lubricating Design: The pump's self-lubricating mechanism and absence of a mechanical seal minimize maintenance needs.

  • Replaceable Cartridge: All moving parts are housed within a replaceable cartridge, allowing for straightforward servicing without replacing the entire unit.

  • Electrical Safety: Always disconnect the power supply before performing any maintenance to prevent electrical shock.

  • Proper Installation: Ensure the pump is installed with the motor in a horizontal position. If mounted vertically, the system's cold fill pressure should be at least 20 psi to ensure proper air purging and prevent flashing.

  • System Flushing: Before operating the circulator, fill the system with tap water or a maximum 50% glycol/water mix. Operate the circulator for 5 minutes at full speed immediately after flushing to purge remaining air from the cartridge.

  • Routine Inspection: Periodically check all bolts and fasteners for tightness, inspect the ignition system, and ensure the cooling system is functioning properly.

  • Operating Conditions: The pump is designed for indoor use with a maximum operating pressure of 125 psi and a temperature range of 40°F to 230°F.

  • Avoid Dry Operation: The bearings are water-lubricated; operating the pump dry can cause damage.

  • Use Appropriate Fluids: Only use water or a maximum of 50% glycol/water mix. The addition of petroleum-based fluids or certain chemical additives can void the warranty.

  • Air Purging: After installation, operate the circulator for 5 minutes at full speed to purge remaining air from the cartridge.