Taco's 1600-868SRP Hi Temp Seal Kit is designed for high-temperature applications. This seal kit is made for Series 1600 and 1900 pumps, providing a reliable seal under demanding conditions.
Product Highlights
The Taco 1600-868SRP Hi Temp Seal Kit offers superior durability and resistance to wear and corrosion. The SEASLIDE C material ensures long-lasting performance and prevents leaks in your pumping systems.
Product Information
Standard Information
Horse Power | 1/40 HP |
---|---|
Voltage | 115V |
Max Flow | 11.5 GPM |
Max Head | 9.5 ft |
Temperature Range | 40°F - 220°F |
Amperage | 0.52 A |
Frequency | 60 Hz |
Weight | 5.58 lbs |
Brand | Taco |
MPN | 006-B4-PNP |
Regular Inspection
Visual Check: Inspect the pump for signs of leaks, corrosion, or other damage. Ensure that all fittings, flanges, and connections are secure.
Mounting: Ensure the pump is properly mounted and aligned to avoid vibration or operational issues.
Cleaning
Exterior Cleaning: Clean the pump’s exterior with a soft, damp cloth to remove dust and dirt. Avoid using abrasive cleaners that could damage the bronze surface.
System Flushing: Flush the system periodically to remove sediment or debris that could clog the pump or impair its operation.
Electrical Components
Wiring Check: Inspect the power cord and electrical connections for wear, fraying, or signs of overheating.
Motor Check: Listen for any unusual noises from the motor, as this could indicate a problem with the bearings or internal components.
Lubrication
Motor Lubrication: Some circulators require regular lubrication. Check the manufacturer's instructions for the proper lubrication schedule and type of lubricant to use.
Avoid Over-Lubrication: Ensure not to over-lubricate as this can attract dust and debris, causing wear on the motor or moving parts.
System Pressure
Pressure Check: Regularly monitor the system pressure. If the circulator is part of a closed-loop system, make sure the pressure remains within the recommended range for optimal performance.
Pressure Relief Valve: Ensure the pressure relief valve is functioning properly to avoid over-pressurization.
Preventive Maintenance
Monitor Flow Rate: If the pump is part of a hydronic system, ensure that it’s maintaining the required flow rate. Low flow could indicate a blockage or wear in the pump.
Protect Against Freezing: If the pump is exposed to freezing temperatures, ensure it is properly insulated to avoid freezing and potential damage.
Replace Worn Parts
Pump Cartridge: If the pump uses a replaceable cartridge, inspect it periodically for signs of wear or damage and replace it as needed.
Seals and O-rings: Check for leaks around the pump seals and O-rings. Replace them if they appear worn or damaged to prevent leaks.