The Taco Electric Water Feeder model EWF024-1 is designed to ensure efficient water control within your HVAC system. Compatible with 24 VAC systems, this feeder is a vital component for any low water cutoff setup, engineered to precisely control the flow of water.

Product Highlights

This 24V electronic water feeder from Taco is essential for controlling water in hydronic heating and cooling systems as well as various types of process equipment. It features selectable operations to customize water feed rates and includes sophisticated diagnostics to monitor and prevent excessive water feed, which can lead to potential flooding.

Features
  • Electronic control mechanisms allow for precise operations.
  • Corrosion-resistant construction offers enhanced durability and longevity.
  • Built with a compact design, facilitating easy installation and maintenance.
Specifications
Horsepower 1/40 HP
Voltage 115V AC
Amperage 0.43 A
Maximum Flow Rate 7 GPM
Max Head 4.5 feet
Material Low Lead Bronze
Dimensions 5.13 x 5.31 x 4.25 inches
Weight 4.41 lbs
Brand Taco
MPN 003-BC4
What our Experts Think
  • Automatic Water Level Maintenance: The Taco EWF024-1 Electric Water Feeder is designed to automatically maintain safe water levels in hydronic heating systems, such as boilers. It works with a low water cutoff (LWCO) to detect low water conditions and adds water when needed, preventing system damage.

  • Selectable Operating Modes: This feeder allows users to select the appropriate number of gallons to be fed, adjust delays before feeding, and monitor for excessive feeding, ensuring optimal performance tailored to specific system needs.

  • Flood Protection Feature: The EWF024-1 includes a flood protection lockout, which suspends system operation if excessive water is fed into the boiler without reaching the normal water level, helping to prevent flooding and potential system damage.

  • Manual Feed Capability: With a manual feed button, the EWF024-1 gives users the ability to top off the boiler whenever needed, offering additional control over the system.

  • Compact and Durable Design: With compact dimensions and durable construction, this water feeder is built to last and perform reliably in demanding hydronic systems.

Q&A

Q: What is the Taco EWF024-1 Electric Water Feeder?
A: The Taco EWF024-1 is a 24V electronic water feeder designed to automatically maintain safe water levels in hydronic heating systems, particularly boilers.

Q: How does the Taco EWF024-1 work?
A: It operates in conjunction with a low water cutoff (LWCO) to add water automatically when levels drop. It offers selectable modes, including fixed feed and LWCO mode, with customizable delays and flood protection.

Q: Is the Taco EWF024-1 compatible with other systems?
A: Yes, it is compatible with various Taco low water cutoffs, ensuring flexibility with different hydronic system setups.

Q: Where can I purchase the Taco EWF024-1?
A: The Taco EWF024-1 is available through multiple distributors and online stores specializing in hydronic system components.

Maintenance Tips

Regular Inspection

  • Check for Leaks: Inspect the pump, flanges, and connection points for any signs of leaks. If leaks are present, tighten any loose fittings or connections to prevent water from escaping.

  • Inspect for Corrosion: Although bronze is resistant to corrosion, it can still show wear over time, especially in harsh water conditions. Regularly check for signs of corrosion on the pump exterior.

Cleaning

  • Exterior Cleaning: Clean the pump exterior periodically using a damp cloth to remove dust, dirt, and mineral deposits. Avoid abrasive cleaners or harsh chemicals that could damage the bronze surface.

  • Clear the Pipes: Check the inlet and outlet pipes for any sediment buildup or debris. Clean the pipes to maintain proper water flow and prevent blockages that could affect the pump's efficiency.

Motor Inspection

  • Check for Noise: Listen for unusual sounds, such as grinding or whirring. Unusual noise can indicate a problem with the motor, bearings, or internal components.

  • Smooth Operation: Ensure the motor runs smoothly without excessive vibration. If vibrations are present, inspect the motor mounting and alignment.

Lubrication (if applicable)

  • Motor Bearings: If your Taco 003-B4 pump requires bearing lubrication, apply the appropriate lubricant as specified in the manufacturer's instructions. Proper lubrication reduces friction and wear on motor bearings.

  • Pump Shaft: Check that the pump shaft rotates freely without resistance. If the shaft becomes stiff, lubrication may be needed.

Electrical Connections

  • Check Wiring: Inspect the electrical wiring for wear, fraying, or signs of overheating. Ensure all electrical connections are secure.

  • Verify Voltage: Ensure the pump is receiving the correct voltage (115V). Incorrect voltage can lead to motor failure or inefficiency.

System Pressure

  • Monitor Pressure: Regularly check the system pressure to ensure it is within the recommended range. Too much or too little pressure can strain the pump and affect its performance.

  • Pressure Relief Valve: Make sure the pressure relief valve is functioning properly to prevent over-pressurization, which could damage the system.

Check for Air in System

  • Air Bleed: Make sure the system is properly bled of air. Air trapped in the pump or pipes can affect the flow and efficiency of the system. If necessary, use the air vent valve to remove trapped air.

Replace Worn or Damaged Parts

  • Seals and Gaskets: Inspect the seals and gaskets for signs of wear. If they are cracked or damaged, replace them promptly to prevent leaks.

  • Pump Components: If the pump or motor is showing significant signs of wear that can't be repaired, consider replacing the unit or individual components.

Winterization (If Applicable)

  • Freeze Protection: In areas where freezing temperatures are common, make sure the pump is properly insulated or removed during the winter months to prevent freeze damage