Taco 2400-40S-3P Potable Circulating Pump 1/6 HP 1 Phase Flange Connection - 2400-40S-3P

FREE SHIPPING
CLEARANCE SALE
80 Peoples are also watching.
Brand: Taco
SKU: 2400-40S-3P
$986.91
$0.00
$986.91
Subtotal: $986.91
clearance sale ends in
00 Hours
00 Minutes
00 Seconds
authorized dealer, shop your favorite brand.
Expert Support,

Dial +1 (888) 575-2099

Limited Supply,

grab it before it's gone.

Lowest prices,

As low as possible.

All Items are brand New,

Never used.

Popular Add-Ons

$200.00

$70.00

$100.00

$30.00

Add-Ons Bundle

$200.00

$70.00

$100.00

$30.00

Bundle Offer

$300.00

$100.00

Recently Viewed Products

Taco 2400-40S-3P Potable Circulating Pump 1/6 HP 1 Phase Flange Connection - 2400-40S-3P

The Taco 2400-40S-3P is a potable water circulating pump that effectively manages hot water needs in various applications. This product features a one-sixth horsepower motor that operates at one-hundred and fifteen volts AC. The pump is designed for in-line installation, allowing for easy integration into existing systems.

Product Highlights

This unit is reliable for hydronic heating and cooling systems. The motor is permanently lubricated and maintenance-free, making it ideal for long-term use.

Features
  • Designed for potable water systems.
  • Features a stainless steel construction for durability.
  • Includes flange gaskets for secure connections.
Specifications

Product Information

Standard Information

Pump Type Circulator
Motor HP 1/6 HP
Max. Flow Rate 32 gpm @ 6 ft
Max. Head 19 ft
Voltage 115V/230V
Connection Size 1-1/4 in, 1-1/2 in
Material Stainless Steel
Weight 15 lbs
Brand Taco
MPN 2400-40S-3P
    What our Experts Think
    • 3-Speed Versatility: The Taco 0013-MSSF2-IFC circulator pump features three selectable speeds, allowing users to optimize performance for different system needs, ensuring maximum efficiency and comfort.

    • Stainless Steel Durability: Constructed with stainless steel, this pump is ideal for potable water applications and ensures long-lasting durability in demanding heating and cooling systems.

    • Integral Flow Check (IFC): The built-in Integral Flow Check prevents gravity flow, reducing installation complexity and costs, while improving pump performance for reliable operation.

    • Quiet and Efficient: Operating without a mechanical seal and utilizing self-lubricating technology, the 0013-MSSF2-IFC circulator pump provides smooth, quiet, and efficient operation, extending the lifespan of the pump.

    • Wide Application Range: Perfect for a variety of hydronic applications, including domestic hot water recirculation, radiant floor heating, fan coil units, and light commercial heating systems.

    Q&A

    Q: What is the Taco 0013-MSSF2-IFC circulator pump?
    A: The Taco 0013-MSSF2-IFC is a 115V, 3-speed stainless steel circulator pump designed for high-flow, high-head applications in residential and light commercial hydronic systems.

    Q: What are the key specifications of the Taco 0013-MSSF2-IFC?

    • Horsepower: 1/6 HP

    • Voltage: 115V, single-phase

    • Speed: 3-speed (0–32 GPM, 0–33 ft head)

    • Max Head: 33 ft

    • Max Pressure: 125 PSI

    • Temperature Rating: Up to 210°F

    • Connection: Flanged, rotated

    • Amperage: 1.65A

    • RPM: 3250

    • Flow Check: Removable Integral Flow Check (IFC)

    • Construction: Stainless steel

    • Warranty: 3 years

    Q: What applications is the Taco 0013-MSSF2-IFC suitable for?
    A: It is ideal for primary boiler loops, large circulation systems, and potable hot water recirculation, and is a direct replacement for certain Grundfos models.

    Q: How does the 3-speed benefit users?
    A: The 3-speed motor allows for flexibility and efficiency, enabling users to adjust the pump's performance to meet specific system requirements.

    Q: Where can I purchase the Taco 0013-MSSF2-IFC?
    A: The Taco 0013-MSSF2-IFC is available from HVAC supply stores and various online retailers.

    Maintenance Tips

    Regular Inspection

    • Check for Leaks: Inspect the pump, flanges, and connection points for any signs of leaks. If leaks are present, tighten any loose fittings or connections to prevent water from escaping.

    • Inspect for Corrosion: Although bronze is resistant to corrosion, it can still show wear over time, especially in harsh water conditions. Regularly check for signs of corrosion on the pump exterior.

    Cleaning

    • Exterior Cleaning: Clean the pump exterior periodically using a damp cloth to remove dust, dirt, and mineral deposits. Avoid abrasive cleaners or harsh chemicals that could damage the bronze surface.

    • Clear the Pipes: Check the inlet and outlet pipes for any sediment buildup or debris. Clean the pipes to maintain proper water flow and prevent blockages that could affect the pump's efficiency.

    Motor Inspection

    • Check for Noise: Listen for unusual sounds, such as grinding or whirring. Unusual noise can indicate a problem with the motor, bearings, or internal components.

    • Smooth Operation: Ensure the motor runs smoothly without excessive vibration. If vibrations are present, inspect the motor mounting and alignment.

    Lubrication (if applicable)

    • Motor Bearings: If your Taco 003-B4 pump requires bearing lubrication, apply the appropriate lubricant as specified in the manufacturer's instructions. Proper lubrication reduces friction and wear on motor bearings.

    • Pump Shaft: Check that the pump shaft rotates freely without resistance. If the shaft becomes stiff, lubrication may be needed.

    Electrical Connections

    • Check Wiring: Inspect the electrical wiring for wear, fraying, or signs of overheating. Ensure all electrical connections are secure.

    • Verify Voltage: Ensure the pump is receiving the correct voltage (115V). Incorrect voltage can lead to motor failure or inefficiency.

    System Pressure

    • Monitor Pressure: Regularly check the system pressure to ensure it is within the recommended range. Too much or too little pressure can strain the pump and affect its performance.

    • Pressure Relief Valve: Make sure the pressure relief valve is functioning properly to prevent over-pressurization, which could damage the system.

    Check for Air in System

    • Air Bleed: Make sure the system is properly bled of air. Air trapped in the pump or pipes can affect the flow and efficiency of the system. If necessary, use the air vent valve to remove trapped air.

    Replace Worn or Damaged Parts

    • Seals and Gaskets: Inspect the seals and gaskets for signs of wear. If they are cracked or damaged, replace them promptly to prevent leaks.

    • Pump Components: If the pump or motor is showing significant signs of wear that can't be repaired, consider replacing the unit or individual components.

    Winterization (If Applicable)

    • Freeze Protection: In areas where freezing temperatures are common, make sure the pump is properly insulated or removed during the winter months to prevent freeze damage

    Related Products

    Brand: Brand
    Example product title
    $986.91
    $0.00
    $986.91
    Brand: Brand
    Example product title
    $986.91
    $0.00
    $986.91
    Brand: Brand
    Example product title
    $986.91
    $0.00
    $986.91
    Brand: Brand
    Example product title
    $986.91
    $0.00
    $986.91